Atomic Absorption Spectrophotometers

Infra-Red Spectrophotometers

UV/Visible Spectrophotometers

Gas Chromatographs

Dedicated Analyzers

High Performance Liquid Chromatographs

Accessories & Supplies

7400 Powerful Integral Software

Software Enhancement by E-SEF

This unique design feature - Encoded Software Enhancement Facility - provided by Cecil Instruments, enables any required additional software module to be released by an encoded entry. The encoded entry required is obtained by telephone, fax or E mail, enabling you to expand your library of methods, without delay, when a new application arises within your laboratory.


Method Operation

Any procedure may be stored as a method in the security code
protected integral memory of the Aquarius instruments. When a
method is recalled, all instrument parameters are automatically set, without operator intervention, thus ensuring that the original conditions are exactly replicated.

Scan Storage

Scans, plots and curves may all be stored, for future use, with confidence in the integrity of the data. Integral memory is provided for up to 100 scans, protected by the operators personal security codes.

Reprocessing

Although scans may be in absorbance, transmittance or derivative format, any scan may be transformed to an alternative format by the very rapid reprocessing facility provided.

Fully Documented Scans

As shown below all scans are fully documented on screen and in
hard copy.

Tables of all peaks and valleys are produced together with instrument, sample and operator details. Scans recalled from the instruments integral memory or by dynamic scan recall are also fully documented.

The screens shown are not two separate displays but part of a continuous display viewed by scrolling.

Benefits

  • Variable or Fixed Bandwidth
  • Large Backlit LCD Screen
  • Screen Scrolling
  • Scrolled Screen Width 430mm
  • Dynamic Scan Recall
  • Full Reference Sample Space
  • Method Storage
  • Spectral Storage
  • Curve Storage
  • Password Protected Storage
  • Multi/Single Cell Kinetics
  • UV Lamp 1500 hours Guarantee


Performance

  • Bandwidth < 2nm or Variable 0.5, 1, 2, 4nm
  • Stability ±0.0001A/H
  • Scan rate 1 to 4000nm/min
  • Wavelength Precision 0.1nm
  • Straylight <0.02%
  • Validation Software

Click on links below for more information.

Powerful Integral Software
Full Reference Beam Space
Display Scrolling of Scans
Superb Versatility
Accurate Scanning & Quantitation
System Functions
Widest Accessory Range

 

<<Back to Main

 

Home & Site Map | Contacts & Locations | About Buck
Application Notes | Markets Served

Buck Scientific
1-800-562-5566
sales@bucksci.com
58 Fort Point Street • East Norwalk, CT 06855
P: 203-853-9444 • F: 203-853-0569