Specifications

Optical System   Fully symmetrical double beam system
All mirrors coated for long life
Monochromator   Modified Czerny-Turner design using 1200
Detectors   Two silicon diode detectors
Self Fest and Calibration   Automatic at switch on
Wavelength Range and Accuracy   190-1100nm; 0.5nm
Wavelength Reproducibility   0.1nm
Wavelength Readout   Digital display on screen
Wavelength Selection   By GOTO key and keypad entry
Optical Bandwidth   <2nm CE7400; 0.5, 1, 2, 4nm CE7500
Stray Light   Less thank 0.02% at 220nm, Nal; and 0.02% at 340nm, NaNO2
Display Screen   Large backlit LCD displays spectra, menus, data, prompts and instrument status.
Display Scrolling   Provides viewing width of 430nm
Derivative Spectra   1st to 4th derivatives
Autozero   Automatic by press button
Photometric Readout   Digital display of A, %T, and C on screen
Photometric Accuracy   ±0.004A at 1A
Photometric Noise   Less than ±0.0001A at 550nm, 2nm b/width
Baseline   Stored in non-volatile memory
Baseline Flatness   ±0.001A (300nm/min, 200-1100nm) 2nm bandwidth
Baseline Stability   Better than ±0.001A/hour
Computer Interface   Bi-Directional RS 232c
Scan Speeds   1-4000nm/min
Wavelength Scale Expansions   1-100nm/cm
Method Storage   30 methods may be stored and retrieved
Method Protection   Each protected by 4 digit passcode
Reaction Kinetics   With plots, reprocessing of data as required, for single cell or up to 6 cells
Overlaid Scans   Up to 8 scans may be overlaid
Cell Programming   Up to 4, 6, or 8 cells
Programme Cycles   From 1 to 9999
Programme Delay (cycle time)   From 0 seconds to 4 days (1 sec resolution)
Wavelength Prgramming   Up to 10 wavelengths. May be combined with a cell programme
Dynamic Scan Recall   Last 25 scans automatically stored on board
Storage of Spectra   100 spectra may be stored code protected
Concentration Curve Fitting   Linear, quadratic or cubic with editing of standards. 30 curves may be sotred protected
Formula Entry and Computation   Complex formulae may be computed
Batch Sampling   Up to 100 samples under internal control
Date and Time Information   Printed from real time clock
Power Requirements   110-250V, 50/60Hz, 170Watts
Dimensions and Weight   635 x 410 x 210mm; 33kg

Click on links below for more information.

Powerful Integral Software
Full Reference Beam Space
Display Scrolling of Scans
Superb Versatility
Accurate Scanning & Quantitation
System Functions
Widest Accessory Range

<<Back to Main

 
 

Home & Site Map | Contacts & Locations | About Buck
Application Notes | Markets Served

Buck Scientific
1-800-562-5566
sales@bucksci.com
58 Fort Point Street • East Norwalk, CT 06855
P: 203-853-9444 • F: 203-853-0569