PrintE-mail


Industrial GC with FID & TCD
View Full-Size Image


Industrial GC with FID & TCD

Price per Unit (piece): $11,350.00

Request Information / Request for Quote

Features

FID & TCD Detectors
On-Column Injector

built-in air compressor

1-meter Silica Gel Column

Temperature Programmable Column Oven

Electronic Pressure Control (EPC) for Carrier & Combustion Gases

4 channel PeakSimple Data System

Programmed oven temperatures from 50°C/min up to 300°C and
20°C/min from 300°C to 450°C

Peak Simple Software for Windows with built-in 4 channel serial
data system

Fast cool oven from 400°C to 50°C in less than 5 minutes for
increased sample throughput

Electronic pressure controls (EPC) maintains flat baselines
over full temperature range, with highly stable retention times

Performs research quality analyses under rigorous lab or field conditions

Over 12 different detector options to choose from for optimal measurement                                 results

910 GC with FID & TCD detectors 30 Meter column, and built-in air compressor.
In the lab, the 910-series GCs perform routine industrial analyses and
complicated research separations easily, generating accurate and reproducible
results. Designed to be durable and portable, the compact 310-series is ideal
for operation in the field, E.P.A. and A.S.T.M. methods can be easily performed
on-site, even in adverse field environments. Use the 910 & 310 and obtain quality
results.

A GC with the versatility to meet your lab’s specific needs. The unique
architecture of the Buck GC systems allow various detector and injector
combinations, so each GC can be configured to meet your specific lab
requirements. The full-size 910-GC can accommodate multiple
injectors and detectors for multi-functional applications, while the smaller
310-GC is equally flexible for portable and field analysis. Automated Analyses
Let the GC do the work so you don’t have to -The Buck 910/310 offer total
control of applicationparameters using PeakSimple software. PeakSimple allows
unlimitedtemperature programming, electronic pressure control, carrier gas
pressure,gas valve position, gas solenoid actuation, autosampler control and
other options. Just program your application parameters into the computer
and let the 910 do the rest.

FID (Flame Ionization Detector) Commonly used for Organic analyses, it is
specific for Hydrocarbon species with a working range from ~10PPM to
10% for C1-C10 compounds. It has a high temperature range, over 400oC,
and can be interfaced with add-on detectors for selective-species
measurements. Solvent and material characterization, environmental samples,
TPH and petroleum analyses are primary applications. Air & Hydrogen are
support gases, using Helium for a carrier gas.

TCD Detector

  • Universal detector
  • Detects from 100% down to 200-500 ppm
  • Easily replaceable filaments
  • Thermostatted up to 275° C
Because it detects all molecules, the Thermal Conductivity Detector
is commonly used for fixed gas analysis (O2, N2, CO, CO2, H2S, NO, etc.)
where the target analytes do not respond well on other, more sensitive
detectors. The TCD can detect concentrations from 100% down to around
100 ppm on a flat baseline with sharp peaks. Where the peak is
broad or the baseline is not flat, detection limits of 300 ppm are more realistic.
For lower detection limits, the HID detector may be more suitable for inorganics,
and the FID detector provides 1ppm detection for hydrocarbon species.

The TCD consists of four tungsten-rhenium filaments in a Wheatstone
bridge configuration.  Electric current flows through the filaments,
causing them to heat up. Carrier gas (usually helium, which has very high
thermal conductivity) flows across the filaments, removing heat at a constant
rate. Two of the filaments are exposed only to carrier gas (reference),
and two are exposed to the carrier/sample flow. When a sample molecule
with lower thermal conductivity than the carrier gas exits the column and
flows across the two sample filaments, the temperature of the filaments
increases. This temperature increase unbalances the Wheatstone bridge
and generates a peak as sample molecules transit through the detector.
A filament protection circuit prevents filament damage by disabling the
current if carrier pressure is not detected by the GC, but cannot prevent
filament damage in all circumstances. The TCD is equipped with
user-replaceable filaments in the event of a burn-out.



This chromatogram shows 0.5mL 10,000 ppm

(1%) CO2 separated from air using a 1-meter Silica

Gel packed column at 80°C.

Gas Chromatography Application Notes

Analysis of Gasoline Range Organics GRO in Soil and Groundwater Using FieldPortable Purge
and Trap GC FID PID.pdf

Analysis of Natural Gas Products by GC with TCD and FID detectors.pdf
Differentiating Polychlorinated Biphenyls PCBs by GC with FID and ECD detectors.pdf
Environmental Analysis of BTEX Compoundsin Soil, Water and Sludge by GC with PID
detector.pdf

Environmental Analysis of Volatile Compoundsin Soil, Water and Sludge by GC with PID
and DELCD detectors.pdf

Measurement of Methyl Isothiocyanate andOther Insecticides by GC with FID and FPD
detectors.pdf

Measurement of Residual Arochlors and otherPesticides in Meat Products by GC with
ECD and NPD detectors.pdf

Pesticide Analysis by GC with ECD-NPD and FID detectors.pdf
Rapid Measurement of Alcohol Ethanol inBeer and Wine Making by GC with FID.pdf
Ultra-Sensitive Coal Tar Distillate Analysisy GC with PID detector.pdf

Buck Scientific 910 GC with heated headspace FID detector(1/3)



DOWNLOAD 910 brochure PDF

Download the Buck Scientific Gas Chromatograph Users Manual










Customer Reviews:

There are yet no reviews for this product.

Write a review for this product!


First: Rate the product. Please select a rating between 0 (poorest) and 5 stars (best).


Now please write a (short) review....(min. 1, max. 2000 characters)


Enter the code below:
Loading captcha image

Characters written:


You may also be interested in this/these product(s)

Gas Line installation kit for Hydrogen
Gas Line installation kit for Hydrogen
$405.00

Gas Line Install Kit for Helium
Gas Line Install Kit for Helium
$405.00


View Cart

My Cart:
0 Items Order Total: $0.00
0 Product
$0.00



Free Shipping

for domestic orders over $500

 

Buck Scientific 2nd annual

Open House Training

September  4-6, 2012

Fill out the

Buck training application.pdf

and send it back to us

to reserve your spot!

Buck Scientific Privacy Policy

Upcoming Events

March 2012
Su Mo Tu We Th Fr Sa
     1 2 3
4 5 6 7 8 9 10
1112The Pittsburg Conference
13The Pittsburg Conference
14The Pittsburg Conference
15The Pittsburg Conference
16 17
18 19 20 21 22 23 24
25ACS Spring Meeting, San Diego CA
26ACS Spring Meeting, San Diego CA
27ACS Spring Meeting, San Diego CA
28ACS Spring Meeting, San Diego CA
29ACS Spring Meeting, San Diego CA
30 31
April 2012
Su Mo Tu We Th Fr Sa
1 2 3 4 5 6 7
8 9 10 11 12 13 14
15 1617Analitica Germany 2012
18Analitica Germany 2012
19Analitica Germany 2012
20Analitica Germany 2012
21
22 23 24 25 26 27 28
29 30     
May 2012
Su Mo Tu We Th Fr Sa
   1 2 3 4 5
6 7 8 9 10 11 12
13 14 15 1617 18 19
20 21 22 23 24 25 26
27 28 29 30 31  
June 2012
Su Mo Tu We Th Fr Sa
      1 2
3 4 5 6 7 8 9
10 11 12 13 14 15 16
17 18 19 20 21 22 23
24 25 26 27 28 29 30