BioAquarius
Symmetrical double beam design, 1.8nm
optical bandwidth. Fully
programmed for bioanalysis. A very capable
general purpose scanning
double beam spectrophotometer.
Bio Spectrophotometers
Specially pre-programmed for bioanalysis
and molecular biology, the BioQuest
and BioAquarius also have all the normal
functions of UV visible spectrophotometers,
scanning, time course plots, single
wavelength measurements in Absorbance,
Concentration or Transmittance, cell
and wavelength programming, method
storage etc.
Protein
Analysis
Preprogrammed methods for all the normal
protein analyses are
provided, these include the following
methods:
Bradford
Lowry
(lowsens.)
Lowry (high sens.)
|
Biuret
BCA
Direct UV. |
Assays
may also be carried out using the
Warburg and Christian 2 or 3 wavelength
methods and the Kalb and Bernlohr
procedures, all of which are preprogrammed.
Nucleic
Acid Assays
Concentration and
purity may be determined by the methods
of
Warburg and Christian, Kalb and Bernlohr
or using user selected parameters.
DNA,
ssDNA, dsDNA, RNA and oligonucleotides
may be quantified and examined for
purity using one wavelength, or two
or three wavelength ratio methods. Molecular
concentration may be determined for
Oligo Samples and theoretical melting
points for DNA samples calculated
using the nearest neighbour interaction
model.
Concentration
Curve Fitting
For more accurate measurements and
for measurements where Beer's law is
not obeyed a straight line quadratic
or cubic curve may be fitted to up
to 30 standards or replicate standards.
Editing of suspect standards may be
carried out and the final curve stored
in code protected memory for future
use.
Reaction Kinetics
Both single and up to 6 cell multi-cell
Kinetics are readily carried out. Water
or thermoelectric temperature control
is available also sample stirring.
Reaction
curves are displayed on screen and
regression analysis applied to the
user selected part of the curves
to calculate results.
Advanced
Kinetics is possible providing such
plots as Michaelis Menton and Lineweaver
Burk etc., from which Km and Vmax
are automatically calculated.
Small
Sample Measurements
A return Micro Sipette system is available
which uses a 75µL cell, measurements
on samples of 300µL or less
may be made with low levels of cross
contamination.
A
special holder accommodates cells of
50µL for measuring valuable
small samples. These cells may be
used in both sample and reference
beams in the BioAquarius instrument.
For
the ultimate in small sampling a
special pipette loaded 5µL
cell with 5mm pathlength is available.
Experimental
Thermal Melt (Tm)
Thermoelectric
temperature programming is available
for thermal melt (Tm) determinations.
A
fully annotated plot of absorbance
against temperature is displayed.
Data may be reprocessed, derivatised,
overlayed, stored or transferred
to a PC.
Method
Generation and Storage
All preprogrammed
methods may be modified by the
user to meet
their requirements. Any modified
method may then be stored as
an additional method in code
protected
memory.
DataStream
- Data to PC
The DataStream system
allows all data to be exported rapidly
and with great ease, to a PC for incorporation
into a spreadsheet or mathematical package
of the users choice - Excel, Grafit etc
- for report generation and mathematical
manipulation.
Program
Any Assay
The Cecil
Assay program software module enables
users to mathematically formulate any
assay for measurement at up to 10 wavelengths.
Rapid text entry of any formula and setting
a wavelength program is all that is required
for automatic measurement of any sample.
A cell program may be incorporated for
multiple automatic sample measurements.
Up to 20 formulae, each with up to 76
characters, may be combined for the most
complex of assays.
Never
before has programming assays for
automatic measurement and computation
been so easy.
Application
Example
A typical experiment
is illustrated here. The scans of protein,
DNA and a sample mixture are shown overlayed
over the range 230-330nm.
An
automatic calculation of the ratios
and the DNA purity of the sample
was made using the pre-programmed
three wavelength ratio method. The
results were automatically tabulated
as shown.

|