Atomic
Absorption Spectrophotometers
Infra-Red Spectrophotometers
UV/Visible Spectrophotometers
Gas Chromatographs
Dedicated Analyzers
High Performance Liquid Chromatographs
Accessories & Supplies

|
| 


| Part
Number: |
Description: |
|
|
Total
Hydrocarbon Analyzer |
| Cuvettes |
| Part
Number: |
Description: |
|
|
Infrasil
quartz, 10mm pathlength |
|
|
Infrasil
quartz, 50mm pathlength |
|
|
Infrasil
quartz, 100mm pathlength |
|
|
Vessel
Cell for Non-Freon Method |
| Holders |
| Part
Number: |
Description: |
|
|
10mm
cuvette holder |
|
|
50mm
cuvette holder |
|
|
100mm
cuvette holder |
|
|
Vessel
cell holder |
| Calibration
Standards |
| Freon
Method |
| Part
Number: |
Description: |
|
|
Reference
Standard for EPA Method
413.2/418.1 TPH
(Photometric Certification-
NIST/US FDA ASTM) |
Detailed
Product Information
Model
HC-404 is a self contained,
fixed wavelength infrared
analyzer designed for rapid
accurate analysis of total
petroleum hydrocarbons in
water, soil and sludge samples.
Features
|
• |
Fixed
wavelength 2924cm -1 (3.42µ)
allows for quick analysis
without unnecessary scanning. |
|
• |
Digital
readout in %T and absorbance,
or in concentration mode
for direct ppm readings. |
|
• |
Accomodates
10, 50, or 100mm quartz
cells for analysis to
1ppm or lower detection
levels. |
| • |
Built-in
scale expansion and extended
linear range for high
concentration, using a
simple 3-step calibration. |
|
• |
Peltier
cooled PbSe detector provides
greater than 2500 to 1
signal to noise ratio,
resulting in the very
best detection levels
and excellent instrument
stability. |
|
• |
Small
foot print requires minimal
lab space. |
| • |
Hot
quartz halogen source
for the highest output
possible. |
|
• |
Instrument
simplicity. Intuitive
controls allow for immediate
operation. |

| Wavelength: |
Fixed
at 2924 cm -1 (3.42
microns) with 30 cm
-1 (0.04 microns) |
| Noise: |
Signal
to noise ratio:
better than 2500:1 |
| Drift: |
0.01
Abs units/hour |
| Photometric
accuracy: |
±1% |
| Response
time: |
10 seconds in Damping
1 and 40 seconds in
Damping 2 |
|
| Ranges: |
0-100%
Transmission; 0-2
Absorbance units;
0-1 and 0-0.1 Concentration |
| Recorder
output: |
Optional |
| Power
requirements: |
115V/230V.A.C.
50-60Hz, 80 Watts |
| Weight: |
20
lbs. |
| Dimensions: |
14"W
x 11"D x 10"H |
|
Typical
Applications:
| Environmental
- Water and soil
quality analysis; UST closure
testing |
Industry
- Monitoring waste water
discharges |
| Laboratories
- Screening samples for
expected organic content
prior to analysis |
Automobiles
- Monitoring service station
waste and water discharge |
| Oil
Sites
- Monitoring discharge of
storage tank washings |
Marine
Transportation
- Testing bilge and ballast
discharge |
|
|
|
|
|
|
|