Injectors

Several injection options are available for the Buck 910/310. Injector types and configurations are selected by the user depending on the particular measurement application, detection limit required and regulatory specifications. All injectors require factory installation.

On-Column Injector

The On-Column injector is supplied standard on all 910/310 GCs. This mode of injection introduces the sample directly into the bore of the column, avoiding the possibility of boiling point discrimination or other uncertainties. A heated injector upgrade is available.

Heated Split/Splitless
The Heated Split/Splitless injector permits the use of narrow-bore capillary columns when needed. The injector temperature is adjustable from ambient to 300ºC and the split flow is adjustable by means of a precision needle valve. This feature can be turned on/off by using a timed event from the PeakSimple software.
10 Port Gas Sampling Valve
The 10 Port Gas Sampling valve can be plumbed in many ways to perform a variety of analytical tasks, providing additional flexibility to the 910. Because the valve oven is immediately next to the column oven, tubing runs are short with no cold spots, which results in sharper peaks. Buck offers many plumbing configurations for optimized gas analyses.

42 Vial Liquid And 20 Vial Internal AutoSampler

The autosampler uses readily available 2ml vials with crimp or screw tops. The autosampler flushes its syringe with the sample itself, so each vial must be filled with at least 1ml of sample. The PeakSimple data system tells the autosampler to flush the syringe, inject the sample and then advance the tray to the next vial position. The autosampler can be used with the on-column, heated, or split/splitless injectors. The 42 vial external Autosampler requires nitrogen, air or helium at 60 psi to actuate the moving parts. The internal 20 vial Autosampler is electronically actuated and is run from peaksimple sample queue. The injection volume is adjustable from 0-3 µl.

Heated Static Headspace Injector
The Heated Static Headspace Injector is useful for the analysis of volatiles, especially where the sample matrix is dirty. A standard 40ml VOA vial is inserted into a thermostatted sleeve, where two needles puncture the septum top of the vial. Purge gas enters through one needle to pressurize the vial and the other needle carries the headspace vapors to the loop of the gas sampling valve or trap.
EPA Method 5030/5035 Compliant Purge & Trap
The 5030 as well as the 5035 Compliant Purge & Trap concentrate the volatile organic compounds (VOCs) in a gas, water, or soil sample onto two adsorbent traps from which they are automatically desorbed into the GC column. The 5035 Purge & Trap is equipped with an adjustable temperature thermostatted sleeve that accommodates a standard 40ml VOA vial containing the water or soil/water sample. The entire sleeve is mechanically agitated during purging to comply with the requirements of EPA Method 5035.

 