- Make setup easy with the user-friendly 7” high-definition color touchscreen and interface
- Choice of measurement modes let you handle a multitude of applications
- Simple connectivity with multiple USB ports for data storage and printer connectivity
- Versatile—compatible with a wide range of interchangeable accessories
Here at Buck Scientific we have always enjoyed selling Jenway products because they are simple to operate, affordable, and reliable. Three things Buck Scientific places enormous importance on. When you buy a Jenway product from Buck, you also get a lifetime of the best customer service in America. Our UV/VIS & IR product Manager Derek Hodgeman has been assisting spectroscopists for over 20 years, and he is at your disposal, just give him a call.
The 7415 spectrophotometer is an advanced spectrophotometer with measurement modes for photometrics, concentration, spectrum scanning, quantification and kinetics. This model will meet the demands of a wide range of applications especially those in clinical, veterinary, environmental and general QC laboratories.


Navigation is fast and intuitive on the large 7” high-definition color touchscreen display. View scans and curves, zoom in and out, and select points right on the screen even when wearing gloves. The home screen provides easy access to measurement modes as well as saved results and methods.
Programmed measurement modes include photometric for single wavelength measurement, concentration for measuring concentration using a standard or factor, spectrum for a high purity scan across the entire wavelength range, quantitation with the ability to create a calibration curve using up to 20 standards, kinetics to monitor change over time, as well as multi-wavelength mode.
Connect to a PC via the Ethernet connection or multiple USB ports readily located on the front of the unit. Save methods and results in the generous 10GB of internal memory for quick recall.
Large sample chamber lid provides easy access to loading and unloading samples and a variety of accessories. The domed design accommodates tall multi-cell changers or test tubes while still maintaining a light-tight sample chamber. The Jenway 7410 and 7415 spectrophotometers, models 83056-21 and -22, are fitted with a 10 mm x 10 mm cuvette holder, accepting a sample volume of 3 mL.
The Jenway 7415 nano spectrophotometer (model 83056-23) is fitted with a micro-volume accessory enabling sample volumes as low as 0.5 µL to be pipetted directly onto the read head, removing the need for cuvettes and conserving valuable samples. It’s the perfect analysis tool to measure the purity and concentration of biological samples.
With CPLive connectivity, you can upload results and protocols safely and securely to the cloud, share data with your colleagues, and simultaneously manage multiple devices through the CPLive app on your computer, tablet, or smartphone. All your information, from one or multiple instruments, is now stored in one secure location, so data is never lost. Create a free account now at CPLive.coleparmer.com to take advantage of unlimited data storage and share your valuable work with colleagues in your lab or around the world.
- Stray Light<0.5% at 340nm and 220nm
- Cloud ConnectedYes
- Source LampXenon lamp
- Beam TypeSingle
- Bandwidth5 nm
- Min Wavelength (nm)198
- Max Wavelength (nm)1000
- Wavelength Accuracy± 2nm
- Wavelength Reproducibility± 0.5nm
- Pathlength (mm)10-100
- Min Photometric - Transmittance (%T)0
- Max Photometric - Transmittance (%T)199.9
- Min Photometric - Absorbance (A)-0.3
- Max Photometric - Absorbance (A)2.5
- Photometric Accuracy±1%T, ±0.01Abs at 1.000 Absorbance
- DetectorSilicon photodiode
- Concentration-300 to 9999
- Data Logging Capability10GB
- OutputUSB Type A x 2; USB Type B x 1; Ethernet RJ45
- Display TypeTouchscreen
- Materials of ConstructionWhite ABS Plastic
- Width (cm)28
- Height (cm)15.6
- Depth (cm)50
- Power (VAC)100 to 240
- Power (Hz)50/60
- Description7415 Scanning UV/Visible Spectrophotometer
UV/VIS Application Notes
Determination of Aspirin concentration using 73 series
Determination of caffeine concentration using 73 series
Determination of glucose in drinks
DNA measurements using TrayCell and 6715
DNA measurements using TrayCell and Genova
Low Sample Volumes using the TrayCell
Protein assays on the Genova
Protein Direct UV measurements using the TrayCell
Protocol: BCA Protein Assay
Protocol: Biuret Protein Assay
Protocol: Bradford Protein Assay
Protocol: Direct UV Protein Assay
Protocol: Direct UV Protein Assay with TrayCell
Protocol: DNA measurements with TrayCell
Protocol: Glucose HK assay using NAD
Protocol: Lowry Protein Assay
Protocol: Nucleic Acid and Protein Assays on 67 series
Protocol: Use of water test kits with 64 and 65 series
Spectrophotometric Analysis of chlorophyll a and b
Use of Microcuvette Holder
Water test kits using 63 series spectrophotometers
Share this Product
More from this collection
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.