Standard Features
The 210/211 is shipped ready for use.  All operating conditions are pre-loaded in the internal computer, including lamp settings, secondary wavelengths, and alternate methods of analysis for over 60 elements by flame, furnace, or hydride techniques.  The three lamp turret has individual controls for alignment and standby mode to keep lamps warm.  Direct report generation to a printer or data linking to the optional Buck Analyst software package is easily done using the parallel and RS232C ports.

Analytical Performance
The Buck 210/211 is a high energy, microprocessor controlled single beam
atomic absorption spectrophotometer.  Solid state electronics and simple optics provide the basis for our superior stability and sensitivity. The
Ebert mount monochromator and user-selectable bandwidth give the system maximum flexibility. Our short-path dynamic nebulizer/burner
configuration is highly efficient. An inert needle, precisely positioned in a
high flow venturi, delivers sample to the corrosion proof impact bead. This
results in a tremendously high nebulization effect for all types of sample matrices


Deuterium Background Correction
This is the oldest and still most commonly used technique, particularly for flame AAS.  In this case, a separate source (a deuterium lamp) with broad emission is used to measure the background absorption over the entire width of the exit slit of the spectrometer. In the 210VGP & Accusys 211 the deuterium lamp is in-line with the hollow cathode lamp, thus eliminating the need for a double beam system. The benefits of a single beam system are more energy, smaller size, lower cost, and a more sensitivity.




Optical Layout

The Buck 210VGP is a single beam AA which has proven itself worldwide as a workhorse.  Our simple, single beam optical layout may buck convention, (no pun intended) but we know it works better.  Let us explain.

Double beam instruments were originally designed to overcome
poor hollow cathode lamp characteristics, noisy Power Supplies, drifting detectors & amplifiers, thermal expansion variations in optical components (mirrors, beamsplitters, mounts, etc.) By using a high light-loss optical component, the beam splitter, to divide the signal beam from the hollow cathode lamp, served to correct for these low performance components; thus halving the available energy to make a sample measurement, compensation between the reference and sample beams was maintained. In later years, the addition of a deuterium continuum lamp for background correction introduced a second beam splitter; thus cutting the hollow cathode lamp energy in half again. This does not even take in to account the 6-10 additional Mirrors used to define the optical path for these large, heavy and expensive (albeit very stable) double beam AAS instruments.

So, after fixing AA instruments for 20 years Buck set out to design a single beam AA just to see if it could be done.  Well it worked, and since 1992 the 210VGP has been delivering superior results due to it's simple optical layout providing a high energy throughput.




DOWNLOAD AA Catalog (PDF)

Download 210-211 AA User manual

Click here for the 210VGP Package Deal!

Atomic Absorption Application Notes


1. AA3001 Sample Preparation of Glass and Ceramic Materials for Atomic Absorption Analysis

2. AA3002 Determination of Trace Lead, Poly-Phenols and Tannins in Wines Using a Single Analytical Instrument

3. AA3003 Determination of Major Components and Trace Contaminants in Assorted Plating Baths by Atomic Absorption Analysis

4. AA3004 Analysis of Whole Blood for Trace Lead (Pb) by Graphite Furnace AAS

5. AA3005 Determination of Wear Metals and Additives (Soaps) in Lubricating Oils by Atomic Absorption

6. AA3006 Determination of Major Electrolytes, Minor Minerals, and Trace Heavy Metals in Physiological Fluids by Flame and Graphite Furnace Atomic Absorption Spectroscopy

7. AA3007 Determination of the Environmental TCLP Metals in Waste-Waters, Solid Wastes, and Soils by Flame Atomic Absorption Spectrophotometry

8. AA3008 Indirect Determination of Gold Purity by Measurement of Impurities with Flame AAS


9. AA3009 Analytical Methodology for the Characterization of Steels and Iron Alloys by Atomic Absorption Analysis


10. AA3011 Evaluation of Mineral Supplements for Content and Purity by Flame/Graphite Furnace AAS

11. AA3012 Determination of Trace Elements in Lead for Battery Application Using Atomic Absorption Analysis


Atomic Absorption EPA Methods



 





Customer Reviews:

  (Wednesday, 18 April 2012)
Rating: 5
We bought our first 210 instrument in the late 90's and added a second instrument soon after which was set up as a graphite furnace AA. The AA has
analyzed over 175,500 samples and is still going strong. The GF instrument has analyzed more than 10,100 samples and is still going strong. These
instruments are used in the environmental industry in an accredited laboratory. As the company owner I can't think of a more reliable, precise and
accurate instrument. Through the years Buck has supported us with friendly and quality telephone support. The service parts are always in stock.
The best part is that when you do need to speak with someone at Buck, there is no phone hassle. You actually speak to real people every time.
rnrnJim Richards, MACS Lab, Inc. 530-274-1470


  (Wednesday, 07 September 2011)
Rating: 5
Thanks to Buck scientific for the 12 years of great service. I bought my first 210 aa in 2000 and lots of accessories over the years and
never had any problems. I just bought a new 210 to update with the times. rnrn-Steve Scott PS thanks Dan Sobin For All the help
rn(928)279-2590


Write a review for this product!


First: Rate the product. Please select a rating between 0 (poorest) and 5 stars (best).


Now please write a (short) review....(min. 1, max. 2000 characters)


Enter the code below:
Loading captcha image

Characters written:


You may also be interested in this/these product(s)

211 Acusys Atomic Absorption Spectrophotometer
211 Acusys Atomic Absorption Spectrophotometer
$14,995.00

210VGP Atomic Absorption starter package
210VGP Atomic Absorption starter package
$12,250.00

205 Atomic Absorption Spectrophotometer
205 Atomic Absorption Spectrophotometer
$9,495.00

The Buck Educational Package
The Buck Educational Package
$24,500.00


View Cart

My Cart:
0 Items Order Total: $0.00
0 Product
$0.00



Free Shipping

for domestic orders over $500

 

Buck Scientific 2nd annual

Open House Training

September  4-6, 2012

Fill out the

Buck training application.pdf

and send it back to us

to reserve your spot!

Buck Scientific Privacy Policy

Upcoming Events

March 2012
Su Mo Tu We Th Fr Sa
     1 2 3
4 5 6 7 8 9 10
1112The Pittsburg Conference
13The Pittsburg Conference
14The Pittsburg Conference
15The Pittsburg Conference
16 17
18 19 20 21 22 23 24
25ACS Spring Meeting, San Diego CA
26ACS Spring Meeting, San Diego CA
27ACS Spring Meeting, San Diego CA
28ACS Spring Meeting, San Diego CA
29ACS Spring Meeting, San Diego CA
30 31
April 2012
Su Mo Tu We Th Fr Sa
1 2 3 4 5 6 7
8 9 10 11 12 13 14
15 1617Analitica Germany 2012
18Analitica Germany 2012
19Analitica Germany 2012
20Analitica Germany 2012
21
22 23 24 25 26 27 28
29 30     
May 2012
Su Mo Tu We Th Fr Sa
   1 2 3 4 5
6 7 8 9 10 11 12
13 14 15 1617 18 19
20 21 22 23 24 25 26
27 28 29 30 31  
June 2012
Su Mo Tu We Th Fr Sa
      1 2
3 4 5 6 7 8 9
10 11 12 13 14 15 16
17 18 19 20 21 22 23
24 25 26 27 28 29 30