| Basic Model Overview |
 |
|
211
Atomic Absorption Spectrophotometer
| • |
Unique
non-flame ignitor provides the safest
instrument start-up |
| • |
Simple
3 button operation for fully automatic
gas controls, ignition and gas switchover
(Air to Nitrous Oxide) |
| • |
Automatic
optimization of analytical parameters
when method files are loaded from
the 211s built-in Methods Library |
| • |
Fully
integrated safety interlocks for gas
pressure sensors, burner head type,
UV flame sensor, drain line trap and
ignitor continuity insure safe operation
of the 211 AAS |
| • |
Upgradable
to the model 220GF back-mounted graphite
furnace for ppb/ ppt trace level analyses |
| • |
Available
autosampler, hydride generator and
cold vapor attachments |
| • |
Internal
microprocessor and software can identify
samples, perform statistical analysis
and graphically display calibration
curves and transient peaks (Hydride
generation & Graphite furnace) |
|
 |
|
210VGP Atomic Absorption Spectrophotometer
| • |
High energy optical system for superior
sensitivity
and detection levels |
| • |
Dual background correction system (D2 &
VGP) for difficult sample matrices |
| • |
Comprehensive microprocessing for methods
storage and data manipulation |
| • |
Three lamp turret for multi-element analysis
|
| • |
Small footprint for mobile applications
|
|
 |
|
210VGP/220 Stabilized Temperature
Graphite Furnace AA
| • |
Fully programmable, computer operated furnace
system |
| • |
Multi-step temperature programming
|
| • |
Methods library sets furnace conditions
automatically |
| • |
Three lamp turret for multi-element analysis
|
| • |
Automatic purge and sheath gas control
including alternate gases |
|
 |
|
205 Atomic Absorption Spectrophotometer
| • |
Internal microprocessor and software can
identify samples, perform statistical
analysis and graphically display calibration
curves. |
| • |
Dual lamp power, one for warm up
|
|
• |
High throughput "Stable Beam"
optical system |
|
• |
Modulated HCL power supply to cancel DC
emission from flame |
| • |
Digital
readout for absorbance, emission,
direct concentration, lamp currents
and PMT voltage |
| • |
Autozero,
curve correction, integration and
high gain damping features |
| • |
Bandpass
resolution from 0.2 - 0.7 - 2.0nm |
| • |
Burner
safety interlock system for nitrous
oxide/acetylene flame operation |
| • |
High
sensitivity detection using quartz
PMT detector |
| • |
Analog
and digital output for chart recorders/PC
data systems |
| • |
Small Size to save bench